Feit com ballast compatibility

Feit com ballast compatibility DEFAULT

Replaced fluorescent tubes with LED tubes, the LEDs only turn on when tapped

Why this often doesn't work

The #1 reason this fails is that the ballas-- hold on. The #1 reason is that Feit Electric is a bunch of junk. Along with Utilitech and Lights of America, these are brands to be avoided. All of them use the "Chinese dumping" business model of disgorge staggering quantities of hastily built lights of cheap parts with little QA - knowing many will fail, but betting on the fact that very few customers bother to return low cost items.

The #2 reason is because of why they're being replaced now. The reason is that something has gone wrong with the light. The logic is, "since I have to buy tubes anyway, now's the time". This doesn't work because the lamps aren't broken, the ballast is. Plug-and-play LEDs require that you "maintain" the ballast forever. On the upside, that means you can easily rollback to real fluorescent tubes; the downside is you are paying four times the cost for a "tube" that has poorer light and only lasts twice as long as a real tube.

If you're going to maintain a ballast anyway, you might as well enjoy the 90+ CRI available from real, actual fluorescent tubes, rather than the "unspecified" from cut-corner LEDs or notchy 80 CRI from good ones.

Remember your ballast requires the smaller, narrow T8 tubes, not the fat old T12 tubes. T12 is also available in 90-98 CRI, but they are not as efficient.

Why this one didn't work

It's one of these two. Couldn't possibly guess, but the usual troubleshooting methods will work.

I would personally save myself the troubleshooting headaches of dealing with an unreliable product like Feit (always wondering if the product is the problem).

The fork in the road

First you need to establish whether the existibg ballast is any good. Try it with known-good fluorescent tubes, or other plug-n-play LEDs. If the ballast is good, you might just stand pat with real fluorescent, or PnP LED if you really want that. That ballast is a modern electronic ballast that should work in the cold, and never flicker. Though I am not a fan of the brand.

If the ballast is bad, there are two ways to go.

  • go "all-in" with LED, and remove the ballast. Now use direct-wire aka ballast-bypass LED tubes, and you will need ones that take power on opposite ends of the tube. (Some take 120V on one end, and have dummy pins on the other; they're dangerous IMO, and on yours, will require you change the tombstones also, which is just too much work.)
  • Replace the ballast with a quality one, such as GE, Advance, Philips, etc. and then use either real fluorescents for best light quality and sane tube cost, or plug-n-play LEDs.
    • If you use an instant-start ballast, it will wire up just like your current ballast; cut the wires on your dead ballast right at the ballast, and use blue wire-nuts to splice the new wires in. Now you are free to mix-and-match LEDs and real fluorescents, as the instant-start drives each tube separately.
    • If you use a rapid-start or programmed-start ballast, you will need to replace all 4 tombstones and rewire 2 wires per tube end. They drive the tubes as matched sets, so no mixing. The benefit to this on LEDs is nil, but on real fluorescents, their preheat sequence greatly extends tube life. A programmed-start crazily extends tube life to the point of being competitive with LED replacements. I use them in inaccessible locations or frequent-switch-on locations (starting a fluorescent accounts for much of the wear, so a soft-start multplies their life greatly).

The incremental cost for better brand of ballast and for rapid/programmed is much less than you'd expect.

answered Oct 12 '19 at 19:43

Sours: https://diy.stackexchange.com/questions/176292/replaced-fluorescent-tubes-with-led-tubes-the-leds-only-turn-on-when-tapped

Plug-and-play vs. ballast-bypass and other linear LED solutions

support image for Plug-and-play vs. ballast-bypass and other linear LED solutions article

If you’re looking to convert your linear fluorescent lamps to linear LED lamps, there are now more options and additional risks to consider.

Thanks to new technology and lower prices, it’s easier and more affordable to upgrade to energy-efficient linear LEDs. 

Proven, well-known traditional lamp manufacturers have lowered their pricing on LED linear lamps (like T8s). It no longer makes sense to choose products made by riskier, lesser-known lamp manufacturers that use lower pricing to attract customers. Additionally, warranties are important. You want to choose a manufacturer who will stand by its product.

Return on investments (ROIs) in less than a year becoming more common today, depending on annual burn time, kWh rates, availability of utility rebates for DLC certified products, etc.

Unlike waiting for the next cool technological gadget, or for prices to drop, there is now a cost correlating to your wait to upgrade to more energy efficient lighting – energy and labor savings that you could be enjoying every day.

Ready to shop for linear LED tubes?

Shop plug-and-play linear T8 LED tubes

Shop ballast-bypass linear T8 LED tubes

Today's T8 linear LED solutions

First, we’re going to break down four options if you’re looking to retrofit from linear fluorescent to linear LED.

1. Plug-and-play or direct fit linear LED (UL type A)

A plug-and-play, or direct fit, linear LED is probably what you're imagining – a simple, one-for-one swap out of the original linear fluorescent lamp. This lamp works directly with the existing fluorescent ballast, so there is no rewiring or ballast change required. But you do want to make sure your ballast is compatible.

Jump ahead to pros and cons.

2. Ballast-bypass, line voltage, or direct wire linear LED  (UL type B)

Bypass the ballast linear LEDs – also known as line voltage or direct-wire linear LEDs – work straight off the line voltage flowing directly to the sockets, requiring you to remove the original fluorescent ballast.

Jump ahead to pros and cons.

3. LED lamp and driver (UL type C)

This linear LED solution requires a ballast change, except instead of replacing the ballast with another ballast, you will replace it with an LED driver and your fluorescent lamps are replaced with linear LED lamps.

Jump ahead to pros and cons.

4. Hybrid or dual technology linear LED (UL type A & B)

Hybrid linear LED lamps are able to work both as a plug and play – with the existing ballast – and, once the ballast peters out, you can remove it and have the lamp run off of line voltage.

Jump ahead to pros and cons.

New call-to-action

Plug-and-play T8 LED pros and cons (UL type A)

Plug-and-play LED tubes (Type A) pros:

  • Simplicity for installer

    The lamp snaps into the existing fixture without any wiring modifications, meaning installation can be done by virtually anyone, as long as your existing ballast is compatible.

  • Safety

    Whenever we can shorten the time someone has to spend dangling from a ladder, things are automatically safer.

  • Lowest cost linear LED solution 

    As a simple one-for-one lamp replacement, the cost of the lamps combined with the minimal labor to install them make them the less expensive option.

  • Ballast protection

    Fluorescent ballasts are designed to control the flow of current or voltage to the sockets, by regulating the current spikes that commonly occur throughout the day.

Plug-and-play LED tubes (Type A) cons:

  • Upfront cost 

    Even with the recent price reductions for linear LEDs, they are still usually 3-5 times the price of the existing fluorescent lamps. The positive news, though, is that it is not uncommon to achieve ROIs in under a year based on energy and labor savings.

  • Ballast compatibility

    While plug-and-play linear LEDs are getting better with ballast compatibility, it's still something you should check. The best way to do this is to take a sample of your common ballasts and make sure they are listed on the manufacturer's approved compatibility list. Our goal is to make lighting easier, so we put together a list of resources where you can check ballast compatibility.

  • Continued ballast maintenance

    While LED lamps don't put the same stress on a ballast that linear fluorescents do, on-going ballast maintenance is still required. 

Shop plug-and-play linear T8 LED tubes

Ballast-bypass T8 LED tube pros and cons (UL type B)

Ballast-bypass LED tube (Type B) pros:

  • No ballast maintenance

    Removing the ballast simplifies the number of fixture components that need to be maintained.

  • Less energy used elimination of ballast draw

    An extra couple of watts is consumed when you pair an LED lamp with a ballast. Since you're bypassing the ballast, the wattage on the lamp is the wattage consumed. This is called ballast factor.

Ballast-bypass LED tube (Type B) cons:

  • Safety risk

    The most significant negative to a ballast-bypass linear LED is the risk of electric shock since the sockets carry line voltage. It's a common practice to place a finger on the lamp pins while you are trying to install it, and this becomes a risky endeavor when using single-ended . Some LED manufacturers have included safety designs to address this, but we always recommend double-ended LED tubes over single-ended for Type B systems. 

  • Fixtures must be rewired

    It can be argued this is a simple process. Disconnect the ballast from the circuit and wire the sockets to line voltage. There are several video tutorials available to demonstrate this task. Interestingly enough, most of these demos are performed with the fixture being rewired laying on a table. If you've done this before, you understand that doing this over your head while balancing on a ladder (and maybe before your morning coffee) can make things more complicated.

  • Exact wiring uncertainty

    Unfortunately, there's no industry-standard wiring schematic for ballast-bypass linear LEDs. Different manufacturers have a variety of approaches that the installer must consider. Among the 31 linear lamps tested in a DOE Caliper report, seven different wiring configurations were used. To complicate matters more, there are two common types of lamps – double-ended and single-ended. The type of lamp and the type of socket (shunted or non-shunted) will have an impact on the wiring. This type of variation among commercial products introduces a new layer of complexity, and for safety reasons we recommend using a qualified electrician.

  • Fluorescent lamp compatibility or snap-back

    We hope that once you retrofit  LED you don't decide to go back to fluorescent, but it's possible that someone could inadvertently install a linear fluorescent lamp in a ballast-bypass fixture. When the LED lamp does need replacing, if you mistakenly try to replace it with a fluorescent, the lamp may not work or could be hazardous. 

  • Title 24 requirements

    In California, there are Title 24 requirements that need to be when you retrofit existing fixtures by replacing the ballast. Please refer to the current Title 24 requirements for more details.

  • Higher initial labor costs

    The need to remove the original fluorescent ballast and rewire the line voltage to the sockets requires more labor than plug-and-play solutions that work with the existing fluorescent ballast.

  • Socket compatibility

    When bypassing the ballast, you may need to change your sockets from the most common shunted sockets to non-shunted sockets. Non-shunted sockets are required if you're using single-ended tubes. This will require a small amount of additional material cost and more labor to replace them all. In addition, some manufacturers may no longer honor the socket warranty if line voltage is direct-wired to their sockets. If you're using double-ended LED tubes, you typically do not need to change your sockets.

    One of our key partners recently came out with a product that could fix the socket compatibility problem. Sylvania's LEDlescent double-ended ballast-bypass lamps are polarity neutral. That means they work in shunted or non-shunted sockets.

Shop ballast-bypass linear T8 LED tubes

LED T8 lamp and driver pros and cons (UL Type C)

LED lamp and driver (Type C) pros:

  • Better energy savings

    LED drivers are more energy efficient than today's ballasts. The wattage of the LED lamp is all that is consumed, whereas when used with a fluorescent ballast, the energy consumed increases by about two watts per lamp on average.

  • Reduced maintenance

    LED drivers are designed to last longer than traditional fluorescent ballasts, thus reducing maintenance costs.

  • No ballast compatibility issues

    LED drivers properly paired with the right linear LED lamps eliminate any ballast compatibility issues that are often common with plug-and-play LED lamps.

  • No snap-back

    The term snap-back refers to replacing the energy efficient lamp with the older, less energy efficient technologies (in this case, linear fluorescents).  When the LED lamp needs replacing, if you try to replace with a fluorescent, the lamp will not be compatible and not function properly with the LED driver.

LED lamp and driver (Type C) cons:

  • Higher initial material costs

    Replacing both ballast with an LED driver and new LED linear lamps come with higher material costs when compared to the plug-and-play solutions. This is offset by the higher energy savings and reduced future labor costs.

  • Higher initial labor costs

    The need to replace the original fluorescent ballast with a new LED driver requires more labor than plug-and-play solutions, which work with the existing fluorescent ballast.

  • Title 24 requirements  

    In California, there are new Title 24 requirements that need to be when you retrofit existing fixtures by replacing the ballast. Most Type C systems will meet Title 24 requirements, but refer to the current Title 24 requirements for more details.

Hybrid T8 LED pros and cons

Hybrid linear LED pros:

  • Greater flexibility 

    The hybrid lamps were designed to work both with the existing fluorescent ballast and by bypassing it. You can start by using it like a plug-and-play lamp and when the ballast fails, you can direct wire it to line voltage.

  • Initial simplicity for installer

    The lamp snaps into the existing fixture without any wiring modifications meaning installation can be done by virtually anyone.

Hybrid linear LED cons:

  • Eventual safety risk

    The most significant negative to bypassing the ballast with a linear LED – once the ballast burns out – is the risk of electric shock since the sockets carry line voltage. Most hybrids system use single-ended LED tubes. It's a common practice to place a finger on the lamp pins while you are trying to install it, and this becomes a risky endeavor with .

  • Fixtures must eventually be rewired

    It can be argued that this is a simple process. Disconnect the ballast from the circuit and wire the sockets to line voltage. There are several video tutorials available to demonstrate this task. Interestingly enough, most of these demos are performed with the fixture being rewired laying on a table. If you've done this before, you understand that doing this over your head while balancing on a ladder (and maybe before your morning coffee) can make things more complicated.
  • DLC listing issues

    To be eligible for potential utility rebates, linear LED lamps usually need to be listed on the Design Lights Consortium (DLC) list of certified products. Hybrid lamps are often listed as DLC certified when used with the fluorescent but are not DLC approved when bypassing the ballast, as it is considered a fixture modification. Some manufacturers may be DLC listed for both.
  • Eventual extra labor

    Once the original fluorescent ballast dies, the need to remove it and rewire the line voltage to the sockets requires additional labor. 

  • Fluorescent lamp compatibility or snap-back

    We hope that once you retrofit to LED you don't decide to go back to fluorescent, but it's possible that someone could inadvertently install a linear fluorescent lamp in the fixture after you rewire it directly to line voltage. When the LED lamp does need replacing, if you mistakenly try to replace it with a fluorescent, the lamp will not be compatible and not function properly.

Other important things to consider when comparing linear LED solutions

1. Proper socket seating

Though the traditional fluorescent sockets have a plastic exterior, they have metal contacts on each side of the interior of the socket.  For a lamp to properly be “seated” in a socket, it needs to snap securely into place to avoid coming loose or moving, and with both of the pins on the LED lamp coming into contact with the metal contacts inside the sockets.

You also want to make sure sockets are not cracked or broken. This could cause socket seating problems. Improper socket seating is the most common cause for fire hazards or melted tubes.

If you want to ensure that you have the proper sockets for your new LED tubes, use this guide. Then, you can purchase the proper sockets (aka tombstones) here.

2. Emergency ballast compatibility

Many of the traditional emergency ballasts used with fluorescent lamps are not compatible with most of the LED linear solutions on the market today. The most common emergency ballasts that compatible with LEDs are often much more expensive the fluorescent versions. This will add to the material cost and labor to the retrofit project. Please make sure your emergency ballast is listed on the manufacturer's compatibility list.

3. Limited dimming options

Though there are currently some good dimmable LED linear options available, the choices are limited and often cost more.

Choosing the right linear LED

The first part of your linear LED decision should involve choosing a reputable manufacturer. You want to work with someone that has put their product through proper testing and will ultimately stand by it. In our experience, some of the best linear LEDs on the market include  Sylvania’s SubstiTUBE products and Philips InstantFit. We also carry products from MaxLite and TCP.

The second part of your decision is which linear LED solution is best for your application. The most common decision is ballast-bypass vs. plug-and-play. For some, the ease of installation on plug-and-play products is attractive, but for others, the simpler long-term maintenance of a direct-wire LED is valuable. Both are viable options that will save your property time and money, but we strongly recommend either plug-and-play or a double-ended ballast-bypass.

Here's why:

Your safety is extremely important.

If you choose ballast-bypass LED tubes, look for a direct-wire lamp that comes with a valid "modification" sticker to affix to the fixture and preserve its UL listing.

Finally, the LED lamp and driver option offers great long-term maintenance savings and light output, but the higher cost will extend your payback.

As you consider the variables that go into a lighting retrofit decision, remember to evaluate your priorities for the project and keep safety first.

 LED Buying Guide to find the best pricing and right specs for LED lighting products

This article has been updated to include new linear LED solutions and current recommendations. It was originally published in September 2015. 

Sours: https://insights.regencylighting.com/plug-and-play-or-ballast-bypass-linear-led
  1. Ola login
  2. The landings uf
  3. Yamaha disklavier tv
  4. Homeless shelter vallejo

4ft 4000K Plug & Play / Direct Replacement LED


overview

Convert your existing fluorescent fixture to LED technology with the Feit Electric T4815840AB/LED/MP/12  4-foot T8 LED lamp. This universal lamp can be installed in fixtures with or without a ballast, making it ideal for  applications where the fluorescent systems are being upgraded to save energy and maintenance costs. With this tube, you can elect to utilize the existing ballast with no rewiring, or install directly without ballast. It produces 1920 lumens of 4000K Cool White light using only 15 watts of electricity. Get instant on to full brightness with relatively cool running performance. Feit Electric T8 dual-mode hybrid linear bulbs have an average life of 50,000 hours / 47 years, are RoHS compliant and 100% mercury-free. Choose a dependable bulb for residential or commercial applications.

Sours: https://www.feit.com/product/4ft-led-4000k-dual-mode-tube/

Her stomach. Knees closer to the chin so that the asshole opens wider. ", I commanded.

Ballast compatibility com feit

Since it was quite warm, I was wearing short stretch navy blue pants and low blue Nike boots, as well as white. Reebok socks and an Adidas jacket. I thought that he should be the first to start somehow, since he clearly adheres to a sporty assertive style. But he didn't move. I already had a total boner in my pants when he got up and turned to me.

Old PL socketed CFL Bulb 1994 FEIT ELECTRIC

Youll break my uterus right now. I told Kostya through moans, he started fucking me somehow abruptly, immediately got me to the uterus and now his head was literally tearing my flesh, hurting. Me. But you love Marina when I tell you I reach the uterus.

You will also like:

They saved the world from total destruction and this nightmare war with their love. Childish love and naivety. They saved humanity and what adults could not do. How many were placed in the cars. Nobody counted, and how many experiences were there with their minds, children's minds.



429 430 431 432 433